NETWORK SETTINGS

Use SonicIP
If set to "yes", the device will announce its IP address over the audio output during device startup.
Default: "yes"

IP Address
Enter the 4 values of the desired device IP address e.g.:
"0.0.0.0" for automatic discovery (DHCP/BOOTP, IPzator, AutoIP)
"192.168.0.12" for an internal LAN
Default: "0.0.0.0"

Netmask
Enter the 4 values of the desired Static IP e.g.:
"0.0.0.0" for a default Netmask depending on the used IP Address.
"255.255.255.0" for a C class network
Default: "255.255.255.0"

Gateway IP Address
Enter the 4 values of the desired Gateway IP address e.g.:
"0.0.0.0" for no Gateway
"192.168.0.1" for a Gateway in a LAN
Note: The Gateway has to be set only when connecting to other devices over the WAN (through a router).
Default: "0.0.0.0"

Primary DNS
In this field you can give the device the desired primary and alternative DNS IP address to be able to connect to URLs (e.g. www.radio.com).
Example: "195.186.1.111"
Default: "0.0.0.0"

Alternative DNS
In this field you can give the device the desired alternative DNS IP address in case the primary DNS is not reachable.
Example: "195.186.4.111"
Default: "0.0.0.0"

Syslog Address
Destination address for syslog messages sent by the BCL program via the SYSLOG command. Set this to your syslog logging machine, if your syslog messages are recorded centrally.
If set to 0.0.0.0, syslog messages are broadcast.
Default: "0.0.0.0"

DHCP Host Name
Name of the device sent in DHCP request. If left empty, a name based on the device's MAC address is generated automatically. Enter up to 15 characters.

Web Server Port
Defines the port where the webserver of the Barix device can be reached. If set to "0" the default HTTP port (80) is used.

"); &LState(2,"%s",28,17,"-->"); Default Ethernet Port
On devices with dual-ethernet connection this parameter selects the default port to be used. In most cases selecting ETH1 is suitable, however some devices (e.g. the PS16) provide Power-over-Ethernet (PoE) functionality on ETH2.
If you change this parameter do not forget to connect the ethernet cable to the proper port on the rear of the device.
Default: "ETH1"

SNMP System Name
SNMP MIB entry for system name (system.sysName.0)

SNMP System Location
SNMP MIB entry for system location (system.sysLocation.0)

SNMP System Contact